soft starter
EBST Soft starter
Application:
The function of EBST soft starter is compatible with the more common types of applications found in the construction, infrastructure or industrial sectors:
1. Centrifugal pumps, pistion pumps
2. Fans
3. Screw compressors etc.
4. Material handling (conveyors etc.)
5. Specialist machines
6. Screw compressor, lifting screw
Function:
Standard: EN60947-2:2000 5.5-30kW CE certified GB8898-1997 CCEE CertificatedRated Current In (A): 23-1000ARated Power Pe(kW):5.5-500kwDegree of protection: IP20(IP40 at request)Shock resisteance: 15kg, 11msAmbient humidity: 95% No dew, no dropping water.Intallation aperture: Φ 6, Φ 7 , Φ 9
Starting mode:
Current Limiting Type:Limting starting current, ruduce starting voltage. Can be adjusted according to demand.Ramp Voltage Type:Start motor smoothly and gradually to reduce the impact on the grid caused by starting current, to prolong the operation life of mechanical transmission.Heavy-load Starting Type: Big startup torqueStopping Type:
Normal.SoftstopControl Type:
Input : Passive switch singnalOutput: RelaySystem protection
a: Short circuit protection: No external quick fuse needed, provides short circuit protection during starting or working or soft stopping stage and will send alarm signal.
b: Ground fault protection: If there is any single-phase ground fault, it will send alarm before stopping running.
c: Over voltage protection: If input voltage exceeds the rated voltage, it will send alarm or stopping running.
d: Overload protection: If the motor is overload, it will give an alarm and stopping running.
e: Phase failure protection: If there is any phase failure in the motor, it will send alarm and stopping running.
f: Reverse phase protection: Will not start the motor and send alarm if reverse phase happened.
Quick selection:
Connection:
soft starter